<img uburebure = "1" ubugari = "1" style = "kwerekana: ntayo" src = "https://www.facebook.com/tr?id=802350791059490&ev=PageView&noscript=1" />

Ibibazo

Amakuru rusange

Niki scaneri ya Launca imbere ya DL-206?

Yashyizwe ahagaragara muri Nzeri, 2020, ifu itagira ifu yimbere ya scaneri DL206 ni ntoya cyane kandi yoroshye kandi yuzuye neza.

Ni irihe tandukaniro riri hagati ya DL-206 na DL-206P?

DL-206P ni verisiyo ishoboka ya ios (idafite mudasobwa), DL-206niyahujwe na mudasobwa imbere.

DL-206 na DL-206P ikoresha software imwe?

Nibyo, bakoresha software imwe.

Nshobora guhagarika porogaramu zindi zitatu kuri Launca intraoral scanner DL-206?

Not, iLaunca imbere ya scaneri DL-206ni igikoresho cyubuvuzi cyagenwe kandi ntabwo cyageragejwe hamwe na software ya gatatu.Porogaramu irwanya virusi ntishobora guhuzwa na skubuntu.

Ibyerekana

Nakora iki hamwe na Launca intraoral scaneri DL-206?

Muri rusange,iLaunca DL-206 ikubiyemo urutonde rwibimenyetso: imanza zisubirana, amakamba hamwe nikiraro, screw yagumanye amakamba, Inlays na onlays, post na core, veneers na DSD, abutment, ibiraro byatewe hamwe nububari, amenyo yuzuye kandi igice, gusaba ibitotsi, guhuza bitaziguye kandi bisobanutse neza.

Nshobora gukoresha Launca intraoral scaneri DL-206 kubibazo bya ortodontique?

Yego.Hamwe nahejuru y'urwasaya rwuzuye, woweUrashobora koherezafungura STLcyangwa PLYamadosiye kugirango asibe aligner yinganda zemera iyi nganda-isanzwe ya dosiye.

Nshobora gusikana scan ya locator cyangwa gukiza abutment kugirango nubake ibicuruzwa byatewe?

Yego.Nka sisitemu ifunguye, yuzuye, abaganga barashobora gufata ibyerekezo bya digitale yimibiri ya scan hamwe na abuttomuburyo bwa digitale kugarura kimwe- na byinshi-byatewe hamwe nibiraro byatewe.

Fungura imiyoboro

Isuzuma rya Launca intraoral DL-206 ni sisitemu ifunze?

Oya. Launca yimbere ya scaneri DL-206 ni sisitemu ifunguye - ifunguye ibikoresho, laboratoire, urusyosisitemunubundi buryo ubwo aribwo bwose bwemerafunguraSTLcyangwa PLYdosiye.

Niba nguze Launca intraoral scanner DL-206, Nshobora gukorana na laboratoire yanjye?

Nibyo, urashobora kubohereza byoroshye dosiye yibisobanuro bya digitale ukoresheje mail cyangwa igicu kugirango wohereze.

Niki dosiye ifunguye STL?

Gufungura dosiye ya STL nuburyo busanzwe bwa dosiye ikoreshwa mukuzigama ibintu-bitatu.Nuburyo busanzwe butatu (3D) bukoreshwa mubuvuzi bw'amenyo ya digitale, cyane cyane ibikoresho bya CAD / CAM.

Nigute abaganga bohereza dosiye za STL hamwe na Launca intraoral scaneri DL-206?

Nyuma yo gusikana imbere, urashobora kohereza dosiye ya STL cyangwa PLY kumuntu uwo ari we wese utanga ibyo

yemera gufungura dosiye ya STL cyangwa dosiye ya PLY.

Ishoramari

Nibangahe Launca intraoral scaneri DL-206 igura angahe?

Launca intraoral scaneri DL-206 nigiciro cyimbere cyimbere hamwe na sisitemu yo kubungabunga make-sisitemu ifunguye rwose, ntamafaranga yo kwiyandikisha yumwaka, ivuriro ryagaragaye rikuze kandi rihamye.Nyamuneka saba LAUNCA MEDICAL uhagarariye kugurisha cyangwa umucuruzi kugirango ubone ibisobanuro birambuye.

Nigute nshobora kugura Launca intraoral scaneri DL-206 mugihugu cyanjye?

Isuzuma rya Launca intraoral DL-206 igurishwa mugihugu cyawe binyuze mubicuruza babiherewe uburenganzira, Niba udashobora kubona abadukwirakwiza iwacu, nyamuneka ohereza iperereza kumasanduku yacu:efax@launcamedical.com, uzabona igisubizo mugihe cyambere.

Nigute natumiza ibikoresho byo gushiraho verisiyo ya mudasobwa igendanwa DL-206P?

Amahitamo menshi yo gushiraho arashobora gutumizwa muburyo butaziguye nabafatanyabikorwa ba Launca, cyangwa urashobora kugura kumuyoboro wawe wongeyeho.

Ni iki gikubiye muri garanti?

Isuzuma rya Launca intraoral scaneri DL-206 hamwe nibindi bikoresho birimo kugura byemejwe amezi 27 uhereye igihe byatangiriye.Gukoresha nabi nka ecran ya ecran ntabwo yapfunditswe.Mugaragaza yarakozwe kuburyo iyo ikoreshejwe mubihe bisanzwe ecran ya ecran iragabanuka.

Hari garanti yaguye?

Nibyo, garanti yagutse irahari.Amasezerano ya serivisi / garanti yaguye ikubiyemo ibice byabigenewe, serivisi kumurongo, nigiciro cyo kohereza.

Ninde nahamagara niba mfite ibibazo (cyangwa nkeneye amahugurwa yinyongera)?

Urashobora kuvugana nababigenewe babiherewe uburenganzira, cyangwa urashobora guhamagara ikigo cya serivisi cya Launca guhamagara cyangwa imeri kuri:service@launcamedical.com

Ese Launca yemerewe abafatanyabikorwa batanga inkunga yo gushiraho no kwishyiriraho?

Biterwa, Ntabwo ari ngombwa kugira kurubuga no gushiraho.Igenamiterere nogushiraho bitangwa hamwe na buri Launca intraoral scaneri DL-206, abafatanyabikorwa ba Channel barahari kugirango bafashe mugushiraho, nibiba ngombwa.

Ese scaneri ya Launca yimbere DL-206 ifite ibikoresho bya TeamViewer kugirango ikigo cya serivisi cya Launca gishobore kugera kure kugirango gikemure ibibazo?

Nibyo, Launca yimbere yimbere ifite ibikoresho bya TeamViewer kugirango ifashe abakiriya mugukemura ibibazo bya sisitemu.

Niba mfite scaneri ya Launca intraoral DL-206, Nabona nte ivugurura rya software hamwe na upgrade?

Kuvugurura porogaramu no kuvugurura bitangwa nabafatanyabikorwa ba Launca nta giciro cyinyongera.

Ni ayahe mahugurwa atangwa mugura Launca intraoral scanner DL-206?

Abafatanyabikorwa ba Launca bazatanga iminsi 1-2 y'amahugurwa kubakiriya bagura Launca intraoral scanner.

Muri rusange, amahugurwa arimo:

1. Kwiga ubumenyi bwibicuruzwa, harimo amakuru yibicuruzwa, ibisobanuro nibindi.;

2. Ubuhanga bwibanze bwo gusikana, inzira yo gusikana;

3. imyitozo yo gusikana icyitegererezo cy amenyo;

4. Imyitozo yo gusikana imbere;

5. Inama zo gufata neza.

Ubushobozi bwa Tekinike Ibiranga inyungu

Niki tekinoroji ya Launca yo gusikana?

Tekinoroji ya 3D ya Launca iri mubyiciro bitatu.

Nabona iki iyo nguze Launca intraoral scanner DL-206?

Kubwoko bworoshye (DL206P):

• Scaneri imwe

• Kamera imwe ya kamera (agasanduku k'amashanyarazi na USB)

• Inama eshatu

• Sikana porogaramu nubuyobozi (software) hamwe ninyandiko zabakoresha

• Ufite umwe

• Dongle imwe

Ubwoko bw'ikarita (DL206):

• Scaneri imwe

• Igare rimwe rifite 21 "ecran-nyinshi

• Inama eshatu

• Sikana porogaramu nubuyobozi (software) hamwe ninyandiko zabakoresha

Scaneri ya DL-206 izahuzwa na sisitemu ya Windows na Mac zombi?

Isuzuma rya DL-206 ryimbere rihuza na Microsoft Windows 10 & 7.Ntabwo ihujwe na sisitemu y'imikorere ya Mac cyangwa verisiyo zabanjirije Microsoft Windows.Byongeye kandi, PC igomba kuba yujuje ibyangombwa byibura PC kugirango ikore ku muvuduko mwinshi.Urutonde rwa GPU I7, RAM 16GB, GPU NVIDIA GeForce GTX 1060, hamwe nibyambu 2 USB (byibuze USB3.0).

Porogaramu yo kugura DL-206 irahagaze wenyine?

Oya, porogaramu yo kugura DL-206 ntabwo ihagaze wenyine;igomba gushyirwaho hamwe na software ya Launca.

Nibihe bingana bya dosiye zohereza hanze byuzuye-scan scan?

Amadosiye yaSTL ni hafi.50 mb kuri scan yuzuye.

.PLY dosiye ni hafi.50 mb kuri scan yuzuye.

Ni ubuhe butumwa bwa Launca intraoral scanner DL-206?

Isuzuma rya Launca intraoral DL-206 hamwe na 20μm ikiraro cyo gusikana neza na 60μm yuzuye ya scan yuzuye.

Isuzuma rya Launca intraoral DL-206 irashobora "kubona" ​​ikoresheje tissue, maraso, n'amacandwe?

Nta sisitemu yo kwerekana imibare ku isoko ishobora kubona binyuze mu ngingo cyangwa mu mazi.Byose bisaba gusubira inyuma no kwigunga kugirango ubashe gufata amashusho.Abaganga b’amavuriro barashobora guhitamo ibicuruzwa bitandukanye kandi inzobere mu buvuzi bwa digitale hamwe na / cyangwa umutoza w’amavuriro bazashobora gutanga ubuyobozi bwibicuruzwa bishobora guhuza neza nubuhanga bwawe.

Isuzuma rya Launca intraoral DL-206 irashobora kwanduzwa?

Nibyo, intoki zirashobora kwanduzwa no kuyihanagura hamwe n’ubucuruzi bwangiza.Imiti yica udukoko twinshi nibisigara bigomba kuvaho.Inama zirashobora guhindurwa muburyo bwa autoclave inshuro 40.

Ese Launca yogusuzuma inama kugirango ihindurwe n'ikigo gikonje?

Nibyo, scan tip yo hanze ikozwe muri polyikarubone irwanya ubushyuhe bwinshi, kubwibyo rero nta ngaruka zishobora kwangirika ziterwa na sterisizione ikonje nka acide peracetike.

Ese scaneri ya Launca intraoral DL-206 ikenera kalibrasi yumurima cyangwa kalibrasi yinganda?

Ntabwo ukeneye kalibrasi yigihe.Wungukire kuri moteri yamashanyarazi & LED yumucyo wo gusikana ibishushanyo mbonera, nta hafi ya scan yukuri igabanuka hamwe nigihe cya optique yibintu byegeranye bihinduka cyangwa imbaraga zumuriro zangirika.

Nigute nshobora kugenzura Launca intraoral scaneri DL-206 nigihe cyo gusikana amashusho?

Urashobora guhora ubona ko nta gutinda kwishusho hagati yibyo urimo gusikana nibyo Launca intraoral scanner DL-206 irimo kwerekana.

Nihe ntera ikora ya Launca intraoral scaneri DL-206?

Ubujyakuzimu bwa DL-206 ni -2mm - + 18mm naho umurima wo kureba (FOV) ni 15.5 x 11mm, DL-206 izakuzanira umwanya munini udasanzwe wo gukora mu ntoki.

Bifata igihe kingana iki kugirango ukore scan imwe hamwe na Launca intraoral scaneri DL-206?

Umunota 1.

form_back_icon
YATSINZWE